Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 19, 2018, 08:58 AM
  • 15 0106_15 0105 _19062018_021054.mp4

Date
06/19/2018
W/O
706913
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00590
PipeID
P11984
Time
1:58 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5734
Sewer Name
15 ABBEY STREET TRUNK
City
LA PUENTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
38
Purpose
Routine Assessment
Project
WO_706913_TV15007_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0106
Downstream MH
15 0105
Dir. of Survey
Downstream
Length Surveyed
223.9 ft.
Total Length
223.9 ft.
Structural Index
3
Structural Quick
423F
Structural Rating
112
O&M Index
2
O&M Quick
2H00
O&M Rating
88
Overall Index
2
Overall Quick
Overall Rating
200
Pipe schematic from manhole 15 0106 to 15 0105
MH: 15 0106MH: 15 0105downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 01062 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start7.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"15.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES40.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"45.1 ft. FM - Fracture Multiple, from 09 to 09 o'clock, within 8 inches of joint: YES, Start51.5 ft. FM - Fracture Multiple, from 09 to 09 o'clock, within 8 inches of joint: YES, Finish54.2 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start83.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"109.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"143 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"157.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"223.1 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish223.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish223.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE223.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0105

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    15.1 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 09 o'clock, within 8 inches of joint: YES, Start

    45.1 ft. - Fracture Multiple, from 09 to 09 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    54.2 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
54.2CM
15.1CL
143TFC
51.5FM
0MWM
109.8TFC
223.1CM
7.3TFC
0MWL
40.7TFA
157.8TFC
45.1FM
83.2TFC
0AMH15 0106
223.1DAGS
223.9MGOCOCKROACHES IN MANHOLE
223.9AMH15 0105
2DAGS

Properties (4)

additional_info
SC359400
custom_field_two
3
customer
LACSD
datetime