Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 31, 2018, 06:19 AM
  • 20 0419_20 0418_30052018_233510.mp4

Date
05/30/2018
W/O
706912
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00749
PipeID
P19367
Time
11:19 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5714
Sewer Name
20 10TH STREET EAST CONNECTION TRUNK
City
PALMDALE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 20
Page No.
07
Purpose
Routine Assessment
Project
WO_706912_TV20001_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
20 0419
Downstream MH
20 0418
Dir. of Survey
Downstream
Length Surveyed
351.1 ft.
Total Length
351.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
312M
O&M Rating
141
Overall Index
2
Overall Quick
Overall Rating
144
Pipe schematic from manhole 20 0419 to 20 0418
MH: 20 0419MH: 20 0418downstream0 ft. MGO - General Observation - CAPPED CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 20 04190 ft. MWM - Water Mark, 20 %of cross sectional area1.2 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: NO2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start21.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"37.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"78.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"86.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"93.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"136.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"159.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"173 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"182.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES227.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"242.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"293.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"304 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"349.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish351.1 ft. AMH - Downstream Manhole, Survey Ends - 20 0418

Observation photos (3)

  • Deposits Attached Grease, 15 %of cross sectional area, from 03 to 05 o'clock,  , within 8 inches of joint: NO

    1.2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: NO

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    182.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
349.4DAGS
159.2TF
293.3TFC
227.1TFA
0MGOCAPPED CONNECTION AT MH 9 O'CLOCK
242.7TFA
1.2DAGS
93.6TFA
0MWL
0AMH20 0419
86.5TFC
351.1AMH20 0418
78.5TFA
37.1TFC
2DAGS
136.2TFC
0MWM
173TFC
304TFC
21.9TF
182.6CM

Properties (4)

additional_info
SC359380
custom_field_two
3
customer
LACSD
datetime