H 0405_A 0930_7102018_095744.mp4
12.2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES
12.2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start
91.8 ft. - Surface Aggregate Projecting, from 08 to 10 o'clock, within 8 inches of joint: NO
264 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - EVERY JOINT
598 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES
606 ft. - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - EVERY JOINT
| Distance | Code | Observation |
|---|---|---|
| 612.9 | SSS | — |
| 598 | SRV | — |
| 60.8 | SSS | — |
| 0 | MWM | — |
| 613 | AMH | 1030 |
| 613 | SRV | — |
| 606 | SRV | EVERY JOINT |
| 91.8 | SAP | — |
| 263.7 | TFC | TWO CONNECTIONS SIDE BY SIDE |
| 612.9 | SAP | — |
| 60.8 | SAV | — |
| 0 | MWL | — |
| 264 | SAP | EVERY JOINT |
| 0 | AMH | 1000 |
| 12.2 | SRV | — |
| 12.2 | SAV | — |
| 91.2 | TF | open |