- Date
- 07/09/2018
- W/O
- 0712243
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00896
- PipeID
- P20974
- Time
- 8:12 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7755
- Sewer Name
- 02 ARTHUR AVENUE TRUNK
- City
- PARAMOUNT
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- 20180709DF_ARTHUR_AVENUE_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 02 2344
- Downstream MH
- 02 2343
- Dir. of Survey
- Downstream
- Length Surveyed
- 10 ft.
- Total Length
- 10 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 10
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 02 2344 to 02 2343 Observation photos (4)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4 ft. - General Photograph

4.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

4.2 ft. - Broken, from 07 to 09 o'clock, within 8 inches of joint: YES