Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 6, 2018, 02:20 PM
  • START_29 0112_762018_082716.mp4

Date
07/06/2018
W/O
0711161
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00273
PipeID
P23898
Time
7:20 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7754
Sewer Name
29 33RD STREET SEWER
City
32nd ST
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20180706SHO_33RD_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0112
Downstream MH
START
Dir. of Survey
Upstream
Length Surveyed
106.8 ft.
Total Length
106.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3111
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 29 0112 to START
MH: 29 0112MH: STARTupstream0 ft. AMH - Upstream Manhole, Survey Ends - BEGINNING OF THE LINE0.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"2.8 ft. RMJ - Roots Medium Joint, from 03 to 05 o'clock, 10 %, within 8 inches of joint: YESR8 ft. RFJ - Roots Fine Joint, at 09 o'clock, within 8 inches of joint: YESR80 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"82.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"106.8 ft. MWL - Water Level, 5 %of cross sectional area106.8 ft. AMH - Downstream Manhole, Survey Begins - MH 112106.8 ft. MWM - Water Mark, 10 %of cross sectional area

Observations (9)

DistanceCodeObservation
106.3TFA
26.8TFA
98.8RFJ
0MWL
24.3TFA
0AMHMH 112
104RMJ
106.8AMHBEGINNING OF THE LINE
0MWM

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2018-07-06T07:20:50-07:00