Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 5, 2018, 04:39 PM
  • C 0350_C 0349_752018_094510.mp4

Date
07/05/2018
W/O
0706969
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00139
PipeID
P09813
Time
9:39 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7752
Sewer Name
C JOINT OUTFALL C - UNIT 8A
City
LONG BEACH
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20180705DF_JOINT_OUTFALL_C_UNIT_8A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Upstream MH
C 0350
Downstream MH
C 0349
Dir. of Survey
Downstream
Length Surveyed
371 ft.
Total Length
371 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole C 0350 to C 0349
MH: C 0350MH: C 0349downstream0 ft. AMH - Upstream Manhole, Survey Begins - 9:43 AM0.1 ft. MWL - Water Level, 25 %of cross sectional area0.1 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start101.7 ft. MGP - General Photograph101.7 ft. MGP - General Photograph156.7 ft. MGP - General Photograph156.7 ft. MGP - General Photograph265.1 ft. MGP - General Photograph265.2 ft. MGP - General Photograph349.9 ft. MGP - General Photograph370 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish370 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 65% MAG370 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish370 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish370.3 ft. MGP - General Photograph370.3 ft. MGP - General Photograph370.3 ft. MGP - General Photograph371 ft. MSA - Survey Abandoned - LOW WATER LEVEL

Observation photos (13)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    101.7 ft. - General Photograph

  • General Photograph

    101.7 ft. - General Photograph

  • General Photograph

    156.7 ft. - General Photograph

  • General Photograph

    156.7 ft. - General Photograph

  • General Photograph

    265.1 ft. - General Photograph

  • General Photograph

    265.2 ft. - General Photograph

  • General Photograph

    349.9 ft. - General Photograph

  • General Photograph

    370.3 ft. - General Photograph

  • General Photograph

    370.3 ft. - General Photograph

Observations (22)

DistanceCodeObservation
370SAP
2SAP
370.3MGP
370SZ65% MAG
370SSS
0.1MWL
349.9MGP
370SRC
371MSALOW WATER LEVEL
265.2MGP
2SSS
370.3MGP
101.7MGP
2SZ65% MAG
101.7MGP
0.1MWM
156.7MGP
2SRC
265.1MGP
370.3MGP
0AMH9:43 AM
156.7MGP

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2018-07-05T09:39:13-07:00