- Date
- 07/02/2018
- W/O
- 0711839
- Weather
- Dry
- Operator/Surveyor
- REVELES
- Sewer ID
- Z00367
- PipeID
- P05224
- Time
- 4:51 AM
- Certificate
- U-115-06022630
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0915
- Sewer Name
- 03 LOS COYOTES DIAGONAL RELIEF TRUNK
- City
- LAKEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 03
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- 20180702VMR_LOS_COYOTES_DIAGONAL_RELIEF_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 03 0527
- Downstream MH
- 03 0526
- Dir. of Survey
- Downstream
- Length Surveyed
- 481.2 ft.
- Total Length
- 481.2 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 4
Pipe schematic from manhole 03 0527 to 03 0526