Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 2, 2018, 05:27 PM
  • H 0296_H 0295_722018_103547.mp4

Date
07/02/2018
W/O
0711946
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00174
PipeID
P10751
Time
10:27 AM
Certificate
U1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0917
Sewer Name
H JOINT OUTFALL H - UNIT 3
City
PICO REVERA
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
21
Purpose
Capital Improvement Program Assesment
Project
20180702SHO_JOINT_OUTFALL_H_UNIT_3
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Upstream MH
H 0295
Downstream MH
H 0296
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole H 0295 to H 0296
MH: H 0295MH: H 0296upstream0 ft. MSA - Survey Abandoned - ZOOMED U/S0 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES - DEBRIS0 ft. SAP - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES0 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO2 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. MWL - Water Level, 5 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - ZOOMING U/S

Observation photos (2)

  • Survey Abandoned - ZOOMED U/S

    2 ft. - Survey Abandoned - ZOOMED U/S

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

Observations (7)

DistanceCodeObservation
0MWM
2MSAZOOMED U/S
2DSZDEBRIS
0MWL
2SAP
2SRV
0AMHZOOMING U/S

Properties (4)

custom_field_three
REBAR IS VISIBLE
custom_field_two
2
customer
LACSD
datetime