- Date
- 07/02/2018
- W/O
- 0712149
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00349
- PipeID
- P02991
- Time
- 12:46 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0918
- Sewer Name
- 02 DISTRICT #2 INTERCEPTOR TRUNK
- City
- COMMERCE
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- 20180702SHO_DISTRICT_2_INTERCEPTOR_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Upstream MH
- 02 1420
- Downstream MH
- 02 1419
- Dir. of Survey
- Downstream
- Length Surveyed
- 2 ft.
- Total Length
- 2 ft.
- Structural Index
- 4
- Structural Quick
- 5131
- Structural Rating
- 8
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 02 1420 to 02 1419 Observation photos (5)

2 ft. - General Observation - WEST AIRLINE

2 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES

2 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES

2 ft. - Survey Abandoned - VIEW OF THE DOWNLEG

2 ft. - General Observation - EAST AIRLINE