- Date
- 06/01/2018
- W/O
- 707282
- Weather
- Dry
- Operator/Surveyor
- K. ADAME
- Sewer ID
- Z00689
- PipeID
- P13860
- Time
- 3:32 AM
- Certificate
- U-0817-07009000
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5632
- Sewer Name
- 18 MILLS AVENUE TRUNK
- City
- WHITTTIER, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_707282_TV18176_JUN2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0044A
- Downstream MH
- 18 0044
- Dir. of Survey
- Downstream
- Length Surveyed
- 281.7 ft.
- Total Length
- 281.7 ft.
- Structural Index
- 3
- Structural Quick
- 3300
- Structural Rating
- 9
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole 18 0044A to 18 0044 Observation photos (4)

2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

118.6 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

185.5 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - ROCK

200.6 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES