Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 6, 2018, 07:36 AM
  • 18 0037_18 0036 _06062018_005153.mp4

Date
06/06/2018
W/O
707282
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00689
PipeID
P13852
Time
12:36 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5638
Sewer Name
18 MILLS AVENUE TRUNK
City
WHITTTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_707282_TV18176_JUN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0037
Downstream MH
18 0036
Dir. of Survey
Downstream
Length Surveyed
308.5 ft.
Total Length
308.5 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 18 0037 to 18 0036
MH: 18 0037MH: 18 0036downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 00370 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. MGO - General Observation - MAGNESIUM COATING START2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start37.7 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 4"49.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"55.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"64.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start64.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish104.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"110.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"129.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES156.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"162.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"207.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"214 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"271.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"277.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"307.8 ft. MGO - General Observation - MAGNESIUM COATING END307.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish307.8 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK308.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0036308.5 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    64.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    129.5 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
2.1MGOMAGNESIUM COATING START
0AMH18 0037
207.9TFC
37.7TB
277.6TFC
308.5AMH18 0036
64.7SAP
2.1SAV
307.8MGOMAGNESIUM COATING END
64.7SAV
308.5MGOCONNECTION AT MH 9 OCLOCK
0MWL
307.8SAP
214TF
129.5FL
55.9TFC
307.8MGOCONNECTION AT MH 3 OCLOCK
156.3TFC
271.9TFC
104.4TFC
0MWM
162.2TFC
49.7TFC
110.5TFC

Properties (4)

additional_info
SC359193
custom_field_two
2
customer
LACSD
datetime
2018-06-06T00:36:08-07:00