Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 1, 2018, 09:56 AM
  • 18 0046_18 0045 _01062018_031115.mp4

Date
06/01/2018
W/O
707282
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00689
PipeID
P13861
Time
2:56 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5632
Sewer Name
18 MILLS AVENUE TRUNK
City
WHITTTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_707282_TV18176_JUN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0045
Downstream MH
18 0046
Dir. of Survey
Upstream
Length Surveyed
298.2 ft.
Total Length
298.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 0045 to 18 0046
MH: 18 0045MH: 18 0046upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 00460.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish44.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"99.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"105.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"162.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"169 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"217.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"220.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"243.9 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES266.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"271.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"296.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start298.2 ft. MWL - Water Level, 10 %of cross sectional area298.2 ft. AMH - Downstream Manhole, Survey Begins - 18 0045298.2 ft. MWM - Water Mark, 35 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    54.3 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
198.9TFC
32.1TFC
80.8TFC
26.4TFC
193TFC
0MWL
0AMH18 0045
78TFC
54.3CL
2.1SAV
254.1TFC
298.2AMH18 0046
135.3TFC
297.4SAV
129.2TFC
0MWM

Properties (4)

additional_info
SC359187
custom_field_two
3
customer
LACSD
datetime
2018-06-01T02:56:06-07:00