- Date
- 06/13/2018
- W/O
- 706728
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00005
- PipeID
- P21320
- Time
- 12:14 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5728
- Sewer Name
- 08 EAST ROAD TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- WO_706728_TV08013_JUN2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 08 0213
- Downstream MH
- 08 0212A
- Dir. of Survey
- Downstream
- Length Surveyed
- 244.5 ft.
- Total Length
- 244.5 ft.
- Structural Index
- 3
- Structural Quick
- 3D21
- Structural Rating
- 71
- O&M Index
- 2
- O&M Quick
- 4131
- O&M Rating
- 105
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 176
Pipe schematic from manhole 08 0213 to 08 0212A Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

58.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

114.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

130.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

187.2 ft. - Roots Medium Lateral, from 09 to 03 o'clock, 40 %, within 8 inches of joint: YES