Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 4, 2018, 09:39 AM
  • H 0553_H 0552 _04062018_025430.mp4

Date
06/04/2018
W/O
701217
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00186
PipeID
P10977
Time
2:39 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5684
Sewer Name
H JOINT OUTFALL H - UNIT 8C
City
BALDWIN PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_701217_TV15170_MAY2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
H 0553
Downstream MH
H 0552
Dir. of Survey
Downstream
Length Surveyed
305.3 ft.
Total Length
305.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1300
O&M Rating
3
Overall Index
1
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0553 to H 0552
MH: H 0553MH: H 0552downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 05532.2 ft. MGO - General Observation - MAG COAT55.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"63.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"119 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"126.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"155.4 ft. RFL - Roots Fine Lateral, at 02 o'clock155.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"157.8 ft. RFL - Roots Fine Lateral, at 02 o'clock157.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"157.8 ft. RFC - Roots Fine Connection, at 02 o'clock159.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"191 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"215.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"231.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"255.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"263.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"305.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK305.3 ft. AMH - Downstream Manhole, Survey Ends - H 0552

Observations (23)

DistanceCodeObservation
157.8RFL
2.2MGOMAG COAT
231.5TFC
155.4RFL
0MGOCONNECTION AT MH 3 O'CLOCK
63.1TFC
155.4TF
157.8TF
157.8RFC
305.3MGOCONNECTION AT MH 3 O'CLOCK
255.4TFC
119TF
126.8TFC
305.3AMHH 0552
263.6TFC
159.4TF
215.5TF
191TF
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
0AMHH 0553
55.1TF

Properties (4)

additional_info
SC359342
custom_field_two
4
customer
LACSD
datetime
2018-06-04T02:39:57-07:00