- Date
- 06/05/2018
- W/O
- 701523
- Weather
- Dry
- Operator/Surveyor
- K. ADAME
- Sewer ID
- Z00827
- PipeID
- P17025
- Time
- 12:26 AM
- Certificate
- U-0817-07009000
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5635
- Sewer Name
- 22 SUNFLOWER TRUNK
- City
- SAN DIMAS, CA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- WO_701523_TV22166_MAY2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0675
- Downstream MH
- 22 0674
- Dir. of Survey
- Downstream
- Length Surveyed
- 300.4 ft.
- Total Length
- 300.4 ft.
- Structural Index
- 1
- Structural Quick
- 311K
- Structural Rating
- 62
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 1
- Overall Quick
- —
- Overall Rating
- 64
Pipe schematic from manhole 22 0675 to 22 0674 Observation photos (3)

2.1 ft. - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

37.5 ft. - Deposits Settled Fine, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start

111.4 ft. - Surface Aggregate Visible, from 04 to 08 o'clock, within 8 inches of joint: NO, Start