Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 4, 2018, 08:05 AM
  • H 0551_H 0550 _04062018_012206.mp4

Date
06/04/2018
W/O
701278
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00185
PipeID
P10975
Time
1:05 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5683
Sewer Name
H JOINT OUTFALL H - UNIT 8B
City
BALDWIN PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_701278_TV15169_MAY2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
H 0551
Downstream MH
H 0550
Dir. of Survey
Downstream
Length Surveyed
584 ft.
Total Length
584 ft.
Structural Index
3
Structural Quick
3V00
Structural Rating
348
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
348
Pipe schematic from manhole H 0551 to H 0550
MH: H 0551MH: H 0550downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 05510 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2.8 ft. MGO - General Observation - MAG COAT5.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start584 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish584 ft. AMH - Downstream Manhole, Survey Ends - H 0550

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0AMHH 0551
0MWM
0MWL
2.8MGOMAG COAT
584SAV
584AMHH 0550
5.3SAV

Properties (4)

additional_info
SC359341
custom_field_two
3
customer
LACSD
datetime
2018-06-04T01:05:56-07:00