Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 20, 2018, 11:21 AM
  • F 0026_F 0025_6202018_045220.mp4

Date
06/20/2018
W/O
0711445
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00033
PipeID
P10116
Time
4:21 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0896
Sewer Name
F JOINT OUTFALL F - UNIT 1
City
PARAMOUNT
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
20180620MDM_JOINT_OUTFALL_F_UNIT_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
69 in.
Upstream MH
F 0026
Downstream MH
F 0025
Dir. of Survey
Downstream
Length Surveyed
252.6 ft.
Total Length
252.6 ft.
Structural Index
4
Structural Quick
5441
Structural Rating
26
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
26
Pipe schematic from manhole F 0026 to F 0025
MH: F 0026MH: F 0025downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:50AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 50% START2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR10 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR16.8 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start51.9 ft. MGO - General Observation - MAG COAT 30% START66.8 ft. SRC - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR84.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE SEVERE AGG ATTACHED117.4 ft. SRC - Surface Reinforcement Corroded, from 10 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR117.4 ft. MGO - General Observation - MAG COAT 60% START252.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR252.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE SEVERE AGG ATTACHED252.1 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG252.1 ft. MGO - General Observation - MAG COAT 60% FINSH252.6 ft. AMH - Downstream Manhole, Survey Ends - 5:10AM

Observation photos (9)

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 50% START

    2 ft. - General Observation - MAG COAT 50% START

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    16.8 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT 30% START

    51.9 ft. - General Observation - MAG COAT 30% START

  • Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    66.8 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE  SEVERE AGG ATTACHED

    84.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE SEVERE AGG ATTACHED

  • Surface Reinforcement Corroded, from 10 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    117.4 ft. - Surface Reinforcement Corroded, from 10 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • General Observation - MAG COAT 60% START

    117.4 ft. - General Observation - MAG COAT 60% START

Observations (20)

DistanceCodeObservation
252.1SRCCIRCUM REBAR
66.8SRCCIRCUM REBAR
252.1SSSBLISTERING PEELING CONCRETE SEVERE AGG ATTACHED
10SRCCIRCUM REBAR
0MWL
2SAMSEVERE AGG
117.4SRCCIRCUM REBAR
0AMH4:50AM
16.8SRC
2MGOMAG COAT 50% START
51.9MGOMAG COAT 30% START
252.1SAMSEVERE AGG
0MGOConn. @ Mh, 9 O' Clock. OPEN
252.1MGOMAG COAT 60% FINSH
252.6AMH5:10AM
117.4MGOMAG COAT 60% START
0MWM
84.8SSSBLISTERING PEELING CONCRETE SEVERE AGG ATTACHED
0MGOConn. @ Mh, 3 O' Clock. Active
2SRCCIRCUM REBAR

Properties (4)

custom_field_three
CIRCUM REBAR CORRODED
custom_field_two
2
customer
LACSD
datetime
2018-06-20T04:21:37-07:00