- Date
- 06/18/2018
- W/O
- 0706884
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00878
- PipeID
- P17727
- Time
- 12:30 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7732
- Sewer Name
- 30 SOUTH BAY CITIES MAIN TRUNK
- City
- MANHATTAN BEACH
- Loc. details
- Sidewalk
- Location Code
- F
- Use of Sewer
- Sanitary Sewer
- District
- District 30
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- 20180618SHO_SOUTH_BAY_CITIES_MAIN_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Upstream MH
- 30 0025A
- Downstream MH
- 30 0025
- Dir. of Survey
- Downstream
- Length Surveyed
- 107 ft.
- Total Length
- 107 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole 30 0025A to 30 0025 Observation photos (3)

21.5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

27.4 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SPORATIC AGG.

79.6 ft. - Tap Break-In Intruding, at 11 o'clock, -, -, within 8 inches of joint: NO, 6", 3" - INTRUDING