- Date
- 05/29/2018
- W/O
- 707007
- Weather
- Heavy Rain
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00218
- PipeID
- P01313
- Time
- 1:43 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5176
- Sewer Name
- 01 SOUTH PARK AVENUE TRUNK
- City
- LOS ANGELES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_707007_TV01204_JUN2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Rectangular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 01 0266A
- Downstream MH
- 01 0266
- Dir. of Survey
- Downstream
- Length Surveyed
- 118.2 ft.
- Total Length
- 118.2 ft.
- Structural Index
- 4
- Structural Quick
- 4100
- Structural Rating
- 4
- O&M Index
- 2
- O&M Quick
- 2111
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole 01 0266A to 01 0266 Observation photos (3)

1.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

2.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

8.3 ft. - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YESR