Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 29, 2018, 10:25 AM
  • 01 0261_01 0260_29052018_034650.mp4

Date
05/29/2018
W/O
707007
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00218
PipeID
P01307
Time
3:25 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5176
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_707007_TV01204_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0261
Downstream MH
01 0260
Dir. of Survey
Downstream
Length Surveyed
324.6 ft.
Total Length
324.6 ft.
Structural Index
4
Structural Quick
4432
Structural Rating
22
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
4
Overall Quick
Overall Rating
28
Pipe schematic from manhole 01 0261 to 01 0260
MH: 01 0261MH: 01 0260downstream0 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH0 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH0 ft. MWM - Water Mark, 70 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02613 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start6.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.8 ft. FM - Fracture Multiple, from 03 to 06 o'clock, within 8 inches of joint: YES62.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"82.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES102.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"141.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"223.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"228 ft. FS - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES237.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES246.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish246.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start263.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"322.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish322.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish324.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0260324.6 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH

Observation photos (7)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 03 to 06 o'clock, within 8 inches of joint: YES

    11.8 ft. - Fracture Multiple, from 03 to 06 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    82.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

    228 ft. - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    237.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    246.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (23)

DistanceCodeObservation
324.6AMH01 0260
0MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
102.4TFC
237.1FM
184.2TF
228FS
6.8CM
322.2FM
246.4FM
62.5TB
0MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
246.3CM
0MWM
263.3TFC
82.3FM
223.9TF
141.5TF
322.2DAGS
324.6MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
0MWL
0AMH01 0261
3DAGS
11.8FM

Properties (4)

additional_info
SC355097
custom_field_two
3
customer
LACSD
datetime
2018-05-29T03:25:51-07:00