Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 1, 2018, 07:18 AM
  • 15 0187_15 0186 _01062018_003227.mp4

Date
06/01/2018
W/O
701427
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00605
PipeID
P12111
Time
12:18 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5680
Sewer Name
15 FERRIS ROAD TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_701427_TV15127_MAY2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0187
Downstream MH
15 0186
Dir. of Survey
Downstream
Length Surveyed
352.7 ft.
Total Length
352.7 ft.
Structural Index
3
Structural Quick
3L12
Structural Rating
191
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
191
Pipe schematic from manhole 15 0187 to 15 0186
MH: 15 0187MH: 15 0186downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 01870 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK17.8 ft. CC - Crack Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES22.3 ft. CC - Crack Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES27.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"38.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start80 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"122 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"124.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"163.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"185.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"223.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"238 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"253.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"286 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"300.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"310.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"333.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"352.7 ft. AMH - Downstream Manhole, Survey Ends - 15 0186352.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Crack Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES

    17.8 ft. - Crack Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES

    22.3 ft. - Crack Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    38.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (24)

DistanceCodeObservation
86.1TF
0MWL
22.3CC
174.7TF
27.9TFC
286TFC
0MWM
163.5TFC
185.1TF
122TFC
0AMH15 0187
352.7AMH15 0186
352.7CM
38.4CM
310.5TF
253.1TF
124.4TFC
0MGOCONNECTION AT MH 3 O'CLOCK
333.6TFC
17.8CC
80TFC
300.4TF
223.8TFC
238TF

Properties (4)

additional_info
SC359338
custom_field_two
3
customer
LACSD
datetime
2018-06-01T00:18:28-07:00