Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 13, 2018, 08:46 PM
  • 29 0108_29 0106_6132018_140020.mp4

Date
06/13/2018
W/O
0711161
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00273
PipeID
P23893
Time
1:46 PM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7730
Sewer Name
29 33RD STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20180613SHO_33RD_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0106
Downstream MH
29 0108
Dir. of Survey
Upstream
Length Surveyed
182.8 ft.
Total Length
182.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 29 0106 to 29 0108
MH: 29 0106MH: 29 0108upstream0 ft. AMH - Upstream Manhole, Survey Ends - BEGINNING OF THE LINE2.1 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"52.1 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"99.8 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"112.4 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: YES, 6"182.8 ft. MWM - Water Mark, 25 %of cross sectional area182.8 ft. AMH - Downstream Manhole, Survey Begins - 0200182.8 ft. MWL - Water Level, 20 %of cross sectional area

Observations (8)

DistanceCodeObservation
0MWM
182.8AMHBEGINNING OF THE LINE
0AMH0200
130.7TBA
0MWL
70.4TFA
180.7TBA
83TFA

Properties (2)

customer
LACSD
datetime
2018-06-13T13:46:21-07:00