Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 12, 2018, 11:47 AM
  • 29 0119_29 0089_6122018_050059.mp4

Date
06/12/2018
W/O
0711161
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00273
PipeID
P23908
Time
4:47 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0890
Sewer Name
29 33RD STREET SEWER
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20180612MDM_33RD_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0089
Downstream MH
29 0119
Dir. of Survey
Upstream
Length Surveyed
300.1 ft.
Total Length
300.1 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 29 0089 to 29 0119
MH: 29 0089MH: 29 0119upstream0 ft. AMH - Upstream Manhole, Survey Ends - 5:40AM3.5 ft. FC - Fracture Circumferential, from 11 to 03 o'clock, within 8 inches of joint: YES - SL3.5 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H16.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open19.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped44.4 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active64.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open66.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped115.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open118.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped122.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open164.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open166.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped215.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open218.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open266 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open269.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped273.1 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE292.1 ft. MGO - General Observation - 8" VCP300.1 ft. AMH - Downstream Manhole, Survey Begins - 5:00AM300.1 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active OUTGOING300.1 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active INCOMING300.1 ft. MWL - Water Level, 5 %of cross sectional area300.1 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • General Observation - 8" VCP

    8 ft. - General Observation - 8" VCP

Observations (24)

DistanceCodeObservation
8MGO8" VCP
0AMH5:00AM
184.4TFOpen
0MGOConn. @ Mh, 9 O' Clock. Active OUTGOING
84.7TFOpen
283.5TFOpen
235.4TFOpen
0MGOConn. @ Mh, 3 O' Clock. Active INCOMING
135.8TFOpen
82TFOpen
0MWL
280.9TFCCapped
181.6TFCCapped
255.7TBActive
300.1AMH5:40AM
27FCHAIRLINE
133.4TFCCapped
30.9TFCCapped
296.6FCSL
34.1TFOpen
178TBOpen
233.2TFCCapped
296.6FCH
0MWM

Properties (5)

additional_info
REVERSE INSPECTION
custom_field_three
SLIGHT FRACTURE
custom_field_two
4
customer
LACSD
datetime
2018-06-12T04:47:32-07:00