Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2018, 06:45 PM
  • 18 0451_18 0450 _08052018_042526.mp4

Date
04/27/2018
W/O
701393
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00675
PipeID
P14302
Time
11:45 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5314
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_701393_TV18097_MAY2018
Sewer Type
Gravity
Material
Polyvinyl Chloride
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0450
Downstream MH
18 0451
Dir. of Survey
Upstream
Length Surveyed
319.1 ft.
Total Length
319.1 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
20
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
24
Pipe schematic from manhole 18 0450 to 18 0451
MH: 18 0450MH: 18 0451upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 045130.4 ft. B - Broken, from 09 to 03 o'clock, within 8 inches of joint: YES30.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish58 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"83.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"109.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"123.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start130.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"144.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES156.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"182.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"208.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"211.7 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES233.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"257.9 ft. CS - Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES259.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"285.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"304.7 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES306 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"319.1 ft. MWL - Water Level, 35 %of cross sectional area319.1 ft. MWM - Water Mark, 50 %of cross sectional area319.1 ft. AMH - Downstream Manhole, Survey Begins - 18 0450

Observation photos (6)

  • Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

    14.4 ft. - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

    61.2 ft. - Crack Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    107.4 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    174.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    195.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 09 to 03 o'clock, within 8 inches of joint: YES

    288.7 ft. - Broken, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
174.9CM
288.6CM
288.7B
162.7TFC
107.4FM
195.5CM
13.1TFC
261.1TFC
111TFC
85.4TFC
319.1AMH18 0451
59.7TFC
0MWL
33.8TFC
61.2CS
0MWM
235.2TFC
137TFC
14.4CM
209.4TFC
188.8TFC
0AMH18 0450

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2018-04-27T11:45:40-07:00