Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2018, 10:01 AM
  • 18 0288_18 0287 _18052018_031701.mp4

Date
05/18/2018
W/O
701118
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00702
PipeID
P14117
Time
3:01 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5614
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
NORWALK, CA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
30
Purpose
Routine Assessment
Project
WO_701118_TV18148_MAY2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0288
Downstream MH
18 0287
Dir. of Survey
Downstream
Length Surveyed
292 ft.
Total Length
292 ft.
Structural Index
3
Structural Quick
423K
Structural Rating
187
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
187
Pipe schematic from manhole 18 0288 to 18 0287
MH: 18 0288MH: 18 0287downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 02880 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"14 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES41.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES53.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"55.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"76 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES104.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"107.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"148.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES153.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"156.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"203.8 ft. FM - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES205.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"208.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"254.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"257.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"289.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish292 ft. AMH - Downstream Manhole, Survey Ends - 18 0287

Observation photos (6)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    14 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    41.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    76 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    148.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

    203.8 ft. - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
0AMH18 0288
2SAV
153.8TFC
14FL
55.6TFC
208.2TFC
292AMH18 0287
205.3TFC
53.4TFC
76FM
0MWM
257.7TFC
289.5SAV
156.7TFC
203.8FM
148.9CM
3.8TFC
254.3TFC
41.9CL
104.8TFC
0MWL
0MGOCONNECTION AT MH 9 O'CLOCK
107.9TFC

Properties (4)

additional_info
SC359169
custom_field_two
3
customer
LACSD
datetime
2018-05-18T03:01:51-07:00