Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 1, 2018, 08:37 AM
  • C 0288_C 0287_01052018_014321.mp4

Date
05/01/2018
W/O
696324
Weather
Dry
Operator/Surveyor
B FUGATE
Sewer ID
Z00134
PipeID
P09748
Time
1:37 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5548
Sewer Name
C JOINT OUTFALL C - UNIT 6E
City
LAKEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
13
Purpose
Routine Assessment
Project
WO_696324_TV19035_APR2018
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
C 0287
Downstream MH
C 0288
Dir. of Survey
Upstream
Length Surveyed
25.2 ft.
Total Length
25.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole C 0287 to C 0288
MH: C 0287MH: C 0288upstream0 ft. MSA - Survey Abandoned - VIEW OF THE U/S SIPHON FROM D/S MH0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish23.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start25.2 ft. AMH - Downstream Manhole, Survey Begins - C 028725.2 ft. MWM - Water Mark, 35 %of cross sectional area25.2 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - VIEW OF THE U/S SIPHON FROM D/S MH

    25.2 ft. - Survey Abandoned - VIEW OF THE U/S SIPHON FROM D/S MH

Observations (6)

DistanceCodeObservation
0AMHC 0287
2.1SAP
25.2MSAVIEW OF THE U/S SIPHON FROM D/S MH
0MWM
25.2SAP
0MWL

Properties (4)

additional_info
SC359304
custom_field_two
3
customer
LACSD
datetime
2018-05-01T01:37:06-07:00