- Date
- 05/25/2018
- W/O
- 0706684
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00325
- PipeID
- P08239
- Time
- 9:03 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0016
- Sewer Name
- A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
- City
- EL MONTE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 22
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180525DF_JOA_1A_SAN_JOSE_CREEK_WRP_INTERCEPTOR
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 60 in.
- Upstream MH
- A 0329
- Downstream MH
- A 0328
- Dir. of Survey
- Downstream
- Length Surveyed
- 650.7 ft.
- Total Length
- 650.7 ft.
- Structural Index
- 4
- Structural Quick
- 5Y2X
- Structural Rating
- 904
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 904
Pipe schematic from manhole A 0329 to A 0328 Observation photos (9)

2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG

120.1 ft. - General Photograph

320.9 ft. - General Photograph

371.1 ft. - General Photograph

382.5 ft. - General Photograph - POSSIBLE RAG/GASKET

392.5 ft. - General Photograph

392.5 ft. - General Photograph - GASKET

505.9 ft. - General Photograph

600.2 ft. - General Photograph