- Date
- 05/04/2018
- W/O
- 695786
- Weather
- Dry
- Operator/Surveyor
- S . LOPEZ
- Sewer ID
- Z00607
- PipeID
- P12331
- Time
- 12:50 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5585
- Sewer Name
- 15 HILL DRIVE EXTENSION TRUNK
- City
- ROSEMEAD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 27
- Purpose
- Routine Assessment
- Project
- WO_695786_TV15033_APR2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 15 0408
- Downstream MH
- 15 0925
- Dir. of Survey
- Downstream
- Length Surveyed
- 13.2 ft.
- Total Length
- 13.2 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 2
- O&M Quick
- 3223
- O&M Rating
- 12
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 14
Pipe schematic from manhole 15 0408 to 15 0925 Observation photos (2)

0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

10.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES