Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 23, 2018, 08:06 PM
  • 08 0136_08 0135_5232018_130933.mp4

Date
05/23/2018
W/O
0706725
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00006
PipeID
P00192
Time
1:06 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7718
Sewer Name
08 FIGUEROA STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Capital Improvement Program Assesment
Project
20180523DF_FIGUEROA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0135
Downstream MH
08 0136
Dir. of Survey
Upstream
Length Surveyed
401.8 ft.
Total Length
401.8 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
8
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
11
Pipe schematic from manhole 08 0135 to 08 0136
MH: 08 0135MH: 08 0136upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:41 PM0.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish0.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish0.4 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)74.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES74.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open126.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"177.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"198.9 ft. FS - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES208.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"227.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"278.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"290 ft. MGP - General Photograph320.8 ft. CC - Crack Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES329.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"343.2 ft. MGP - General Photograph352.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"365.9 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start379.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"399.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start399.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start401.8 ft. MWM - Water Mark, 30 %of cross sectional area401.8 ft. AMH - Downstream Manhole, Survey Begins - 1:08 PM401.8 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (8)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

    35.9 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

  • General Photograph

    58.6 ft. - General Photograph

  • Crack Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES

    81 ft. - Crack Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES

  • General Photograph

    111.8 ft. - General Photograph

  • Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

    202.9 ft. - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    327.7 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
275.7TFC
58.6MGP
0MWM
326.9TFOpen
401.8AMH1:41 PM
327.7CL
111.8MGP
0AMH1:08 PM
401.4SSS
174.5TFC
2SSS
401.4RFJ
72.1TFC
193.3TFC
81CC
401.4DAGS
2.2DAGS
49.2TFC
35.9RFJ
0MWL
123.5TFC
22.3TFC
202.9FS
224.3TFA
401.4MGOGREASE THROUGHOUT THE REACH (5%)

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2018-05-23T13:06:59-07:00