- Date
- 05/22/2018
- W/O
- 0706724
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00722
- PipeID
- P15273
- Time
- 10:51 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7717
- Sewer Name
- 19 EAST ARTESIA TRUNK, SECTS 1,2,3,&5
- City
- CERRITOS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180517DF_EAST_ARTESIA_TRUNK_SECTS_1_2_3_5_
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 19 0081
- Downstream MH
- 19 0080
- Dir. of Survey
- Downstream
- Length Surveyed
- 63.2 ft.
- Total Length
- 63.2 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 3
- O&M Quick
- 4123
- O&M Rating
- 10
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 19 0081 to 19 0080 Observation photos (7)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

15.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

28.3 ft. - General Photograph

28.3 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

44.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

62.5 ft. - General Photograph

62.5 ft. - General Photograph