Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2016, 06:13 AM
Date
07/18/2016
W/O
574316
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00294
PipeID
P03310
Time
11:13 PM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3657
Sewer Name
02 OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
WO_574316_TV02111_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 0752
Downstream MH
02 0853
Dir. of Survey
Downstream
Length Surveyed
216.9 ft.
Total Length
216.9 ft.
Structural Index
2
Structural Quick
3124
Structural Rating
11
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
13
Pipe schematic from manhole 02 0752 to 02 0853
MH: 02 0752MH: 02 0853downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 07520 ft. MWL - Water Level, 20 %of cross sectional area3.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start32.6 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES34.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"37.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"51.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES76.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"79.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"84.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES119.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"122.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"133.3 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES161.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"165.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"181.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES210.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"213.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"216.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish216.9 ft. AMH - Downstream Manhole, Survey Ends - 02 0853

Observation photos (8)

  • Water Mark, 25 %of cross sectional area

    0 ft. - Water Mark, 25 %of cross sectional area

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    32.6 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    37.3 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    79.7 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    119.4 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    122.4 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    133.3 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    210.9 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"

Observations (21)

DistanceCodeObservation
51.1CL
213.6TFC
122.4TFA
79.7TFC
119.4TFC
3.4DAGS
216.9DAGS
161.9TFC
34.2TFC
37.3TFA
76.8TFC
0MWM
216.9AMH02 0853
133.3CL
210.9TFA
181.8CL
165.1TFA
32.6CM
0AMH02 0752
0MWL
84.7CL

Properties (4)

additional_info
SC305536
custom_field_two
3
customer
LACSD
datetime
2016-07-18T23:13:00-07:00