Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 25, 2016, 10:02 AM
Date
07/25/2016
W/O
574316
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00294
PipeID
P03285
Time
3:02 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3661
Sewer Name
02 OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
WO_574316_TV02111_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0729A
Downstream MH
02 0730
Dir. of Survey
Upstream
Length Surveyed
132.1 ft.
Total Length
132.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 0729A to 02 0730
MH: 02 0729AMH: 02 0730upstream0 ft. MGO - General Observation - DAMGAGE OF TROUGH0 ft. AMH - Upstream Manhole, Survey Ends - 02 07302 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish30.5 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"32 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"43 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 4"44.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"127.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"129 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start132.1 ft. AMH - Downstream Manhole, Survey Begins - 02 0729A132.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE132.1 ft. MWM - Water Mark, 20 %of cross sectional area132.1 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (8)

  • General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE

    0 ft. - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE

  • Water Level, 5 %of cross sectional area

    0 ft. - Water Level, 5 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    4.2 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 4"

    89.1 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"

    101.6 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Finish

    130.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

  • Upstream Manhole, Survey Ends - 02 0730

    132.1 ft. - Upstream Manhole, Survey Ends - 02 0730

Observations (13)

DistanceCodeObservation
0AMH02 0729A
0MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
101.6TBA
3.1DAGS
100.1TFC
132.1MGODAMGAGE OF TROUGH
132.1AMH02 0730
0MWM
89.1TBA
4.2TFA
130.1DAGS
87.8TFC
0MWL

Properties (4)

additional_info
SC305540
custom_field_two
4
customer
LACSD
datetime
2016-07-25T03:02:00-07:00