- Date
- 07/19/2016
- W/O
- 574316
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00294
- PipeID
- P03367
- Time
- 10:11 PM
- Certificate
- U-507-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3658
- Sewer Name
- 02 OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
- City
- DOWNEY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 24
- Purpose
- Routine Assessment
- Project
- WO_574316_TV02111_JUNE2016
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 02 0801
- Downstream MH
- 02 0800
- Dir. of Survey
- Downstream
- Length Surveyed
- 301.4 ft.
- Total Length
- 301.4 ft.
- Structural Index
- 3
- Structural Quick
- 3J00
- Structural Rating
- 171
- O&M Index
- 3
- O&M Quick
- 4131
- O&M Rating
- 11
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 182
Pipe schematic from manhole 02 0801 to 02 0800 Observation photos (6)

0 ft. - General Observation - CONNECTION AT THE MH 3 O'CLOCK ACTIVE

0 ft. - Water Mark, 25 %of cross sectional area

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

3 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

80.1 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

291.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES