Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 11, 2018, 08:39 AM
  • 01 0985_01 0984_5112018_015315.mp4

Date
05/11/2018
W/O
0705547
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00228
PipeID
P01823
Time
1:39 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0853
Sewer Name
01 WRIGHT ROAD TRUNK
City
MAYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
02
Purpose
Routine Assessment
Project
20180511MDM_WRIGHT_ROAD_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
01 0985
Downstream MH
01 0984
Dir. of Survey
Downstream
Length Surveyed
237.8 ft.
Total Length
237.8 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 01 0985 to 01 0984
MH: 01 0985MH: 01 0984downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:50AM0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN8.2 ft. MGO - General Observation - 21 " VCP8.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE18.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H66.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open68.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open108.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open110.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open145.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H146.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open149 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open190.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open203.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open215.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H237.4 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active237.4 ft. MGO - General Observation - PIPE APPEARS AS 18" VCP237.8 ft. AMH - Downstream Manhole, Survey Ends - 2:15AM

Observation photos (1)

  • General Observation - 21 " VCP

    8.2 ft. - General Observation - 21 " VCP

Observations (20)

DistanceCodeObservation
237.8AMH2:15AM
215.7FLH
8.2MGO21 " VCP
0AMH1:50AM
0MWL
108.3TFOpen
145.6FCH
203.5TFOpen
0MWM
18.6FCH
66.4TFOpen
110.5TFOpen
0MGOConn. @ Mh, 3 O' Clock. OPEN
149TFOpen
237.4MGOConn. @ Mh, 3 O' Clock. Active
237.4MGOPIPE APPEARS AS 18" VCP
146.4TFOpen
68.9TFOpen
8.2FLHAIRLINE
190.6TFOpen

Properties (3)

custom_field_two
4
customer
LACSD
datetime