Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 20, 2018, 07:45 AM
  • 22 0495_22 0494 _20042018_005626.mp4

Date
04/20/2018
W/O
695664
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00800
PipeID
P16834
Time
12:45 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5573
Sewer Name
22 COVINA CONNECTION EXTENSION TRUNK
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
WO_695664_TV22031_APR2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
22 0495
Downstream MH
22 0494
Dir. of Survey
Downstream
Length Surveyed
168.4 ft.
Total Length
168.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 22 0495 to 22 0494
MH: 22 0495MH: 22 0494downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 04950 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 02 to 10 o'clock, within 8 inches of joint: YES, Start26.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"29.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"78.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"81.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"129.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"132.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"166.1 ft. SAP - Surface Aggregate Projecting, from 02 to 10 o'clock, within 8 inches of joint: YES, Finish168.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK168.4 ft. AMH - Downstream Manhole, Survey Ends - 22 0494

Observation photos (1)

  • Surface Aggregate Projecting, from 02 to 10 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 02 to 10 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
26.7TFC
0AMH22 0495
129.5TFC
0MWL
2SAP
168.4MGOACTIVE CONNECTION AT MH 3 O'CLOCK
81.2TFC
0MWM
132.3TFC
78.1TFC
166.1SAP
29.8TFC
168.4AMH22 0494

Properties (4)

additional_info
SC358532
custom_field_two
2
customer
LACSD
datetime
2018-04-20T00:45:18-07:00