29.5 ft. - Crack Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES
49.9 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES
53.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
120.7 ft. - Deposits Settled Compacted, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES
139.9 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
184.8 ft. - Joint Offset Medium
281 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 246.6 | TF | — |
| 144.6 | TF | — |
| 0 | AMH | 29 0195 |
| 139.9 | CL | — |
| 281 | FC | — |
| 294.7 | TFC | — |
| 301.8 | ACOM | 29 0195A |
| 147.1 | TFC | — |
| 184.8 | JOM | — |
| 96.2 | TF | — |
| 186.3 | TF | — |
| 53.1 | CM | — |
| 54.7 | TF | — |
| 120.7 | DSC | — |
| 75.4 | CM | — |
| 76 | JOL | SOIL VISIBLE - POSSIBLE BROKEN PIPE , 10 TO 2 O'CLOCK @ 76' |
| 0 | MWL | — |
| 29.5 | CM | — |
| 249.5 | TFC | — |
| 93.6 | TF | — |
| 2 | MGO | SPALLING FROM 8 TO 4 O'CLOCK @ 2' MARK TO 295' |
| 69.2 | TFC | — |
| 0 | MWM | — |
| 297.2 | TF | — |
| 204.4 | TF | — |
| 196 | TFC | — |
| 42.9 | TFC | — |
| 49.9 | CM | — |