C 0312A_C 0312_6212017_125548.mp4
8.1 ft. - General Observation - MAG COAT, 8 TO 4 OCLOCK, 50%
8.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
22.3 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"
24.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
44.5 ft. - General Photograph - EXPOSED AGGREGATE VISIBLE
78.1 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES
157.6 ft. - Downstream Manhole, Survey Ends - 1:13 PM
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 157 | SSS | — |
| 78.1 | SRV | — |
| 119.9 | CC | — |
| 70.3 | MGO | ROACHES THROUGHOUT THE REACH |
| 0 | MGO | CONNECTION AT MH, 9 OCLOCK, ACTIVE |
| 24.4 | SAV | — |
| 8.1 | MGO | MAG COAT, 8 TO 4 OCLOCK, 50% |
| 157 | SAV | — |
| 44.5 | MGP | EXPOSED AGGREGATE VISIBLE |
| 110.7 | CC | — |
| 0 | MWL | — |
| 0 | MGO | CONNECTION AT MH, 3 OCLOCK, ACTIVE |
| 0 | MGO | ROACHES AT MH > 50 |
| 0 | AMH | 12:55 PM |
| 157.6 | AMH | 1:13 PM |
| 8.1 | SSS | — |
| 22.3 | TFC | — |