C 0315_C 0314_6212017_085840.mp4
C 0315_C 0314_6212017_091315.mp4
8.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
8.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
40.4 ft. - General Observation - POSSIBLE MAG COAT THROUGHOUT THE REACH, FROM 8 TO 4 OCLOCK, 25%
45.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES
45.5 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - GREASE DEPOSITS, 5 %
45.5 ft. - Survey Abandoned - DUE TO GREASE FROM 8 TO 4 OCLOCK, 25 %
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 45.1 | DAGS | — |
| 0 | MWM | — |
| 8.3 | SSS | — |
| 45.5 | MGO | ROACHES IN LINE > 50 |
| 8.4 | SAP | — |
| 40.4 | MGO | POSSIBLE MAG COAT THROUGHOUT THE REACH, FROM 8 TO 4 OCLOCK, 25% |
| 45.5 | TFA | GREASE DEPOSITS, 5 % |
| 45.5 | SSS | — |
| 45.5 | MSA | DUE TO GREASE FROM 8 TO 4 OCLOCK, 25 % |
| 45.5 | SAP | — |
| 0 | MGO | ROACHES > 50 AT MH |
| 0 | AMH | 09:00 AM |