Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2017, 03:35 PM
  • C 0315_C 0314_6212017_085840.mp4

  • C 0315_C 0314_6212017_091315.mp4

Date
06/21/2017
W/O
0630229
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
Z00135
PipeID
P09778
Time
8:35 AM
Certificate
PENDING
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7440
Sewer Name
C JOINT OUTFALL C - UNIT 6F
City
CERRITOS
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20170621MI_JOINT_OUTFALL_C_UNIT_6F
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Upstream MH
C 0314
Downstream MH
C 0315
Dir. of Survey
Upstream
Length Surveyed
45.5 ft.
Total Length
45.5 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole C 0314 to C 0315
MH: C 0314MH: C 0315upstream0 ft. MGO - General Observation - ROACHES IN LINE > 500 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - GREASE DEPOSITS, 5 %0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - DUE TO GREASE FROM 8 TO 4 OCLOCK, 25 %0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.4 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES5.1 ft. MGO - General Observation - POSSIBLE MAG COAT THROUGHOUT THE REACH, FROM 8 TO 4 OCLOCK, 25%37.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start37.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start45.5 ft. MWM - Water Mark, 10 %of cross sectional area45.5 ft. MWM - Water Mark, 25 %of cross sectional area45.5 ft. MGO - General Observation - ROACHES > 50 AT MH45.5 ft. AMH - Downstream Manhole, Survey Begins - 09:00 AM

Observation photos (6)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - POSSIBLE MAG COAT THROUGHOUT THE REACH, FROM 8 TO 4 OCLOCK,  25%

    40.4 ft. - General Observation - POSSIBLE MAG COAT THROUGHOUT THE REACH, FROM 8 TO 4 OCLOCK, 25%

  • Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    45.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - GREASE DEPOSITS, 5 %

    45.5 ft. - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - GREASE DEPOSITS, 5 %

  • Survey Abandoned - DUE TO GREASE FROM 8 TO 4 OCLOCK, 25 %

    45.5 ft. - Survey Abandoned - DUE TO GREASE FROM 8 TO 4 OCLOCK, 25 %

Observations (13)

DistanceCodeObservation
0MWM
45.1DAGS
0MWM
8.3SSS
45.5MGOROACHES IN LINE > 50
8.4SAP
40.4MGOPOSSIBLE MAG COAT THROUGHOUT THE REACH, FROM 8 TO 4 OCLOCK, 25%
45.5TFAGREASE DEPOSITS, 5 %
45.5SSS
45.5MSADUE TO GREASE FROM 8 TO 4 OCLOCK, 25 %
45.5SAP
0MGOROACHES > 50 AT MH
0AMH09:00 AM

Properties (3)

custom_field_two
5
customer
LACSD
datetime
2017-06-21T08:35:26-07:00