Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 24, 2017, 09:55 AM
  • B 0038_B 0956 _24052017_030227.mp4

Date
05/24/2017
W/O
635624
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00113
PipeID
P22232
Time
2:55 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4505
Sewer Name
B JOINT OUTFALL B - UNIT 9A
City
COMPTON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
09
Purpose
Routine Assessment
Project
WO_635624_TV08124_MAY2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
78 in.
Width
78 in.
Upstream MH
B 0038
Downstream MH
B 0956
Dir. of Survey
Downstream
Length Surveyed
24.5 ft.
Total Length
24.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole B 0038 to B 0956
MH: B 0038MH: B 0956downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 00380 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area17.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"24.5 ft. MSA - Survey Abandoned - FLOW NOT PULLING BOAT

Observations (5)

DistanceCodeObservation
0AMHB 0038
24.5MSAFLOW NOT PULLING BOAT
0MWM
17.9TF
0MWL

Properties (5)

additional_info
SC345315
custom_field_two
5
customer
LACSD
datetime
2017-05-24T02:55:33-07:00
lining
FR POLY LINE