Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 29, 2017, 11:13 AM
  • 02 0304_02 0303_6292017_042110.mp4

Date
06/29/2017
W/O
0647471
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00251
PipeID
P02618
Time
4:13 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0580
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
19A
Purpose
Routine Assessment
Project
20170626MDM_DOWNEY_BELLFLOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0304
Downstream MH
02 0303
Dir. of Survey
Downstream
Length Surveyed
134.5 ft.
Total Length
134.5 ft.
Structural Index
2
Structural Quick
322D
Structural Rating
54
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
58
Pipe schematic from manhole 02 0304 to 02 0303
MH: 02 0304MH: 02 0303downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:25AM8 ft. MGO - General Observation - WHITE BUUILD UP ON PIPE30.9 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT30.9 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE39.4 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H43.1 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL43.1 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL47.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open54.1 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H54.1 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - SL70.5 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H70.5 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H74.8 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL74.8 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL86.7 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H86.7 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H90.4 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H94.4 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - H94.4 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H102.7 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H102.7 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H106.5 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H106.5 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - SL110.6 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL114.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H122.7 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL122.7 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H131.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL131.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL131.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped134.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active134.5 ft. AMH - Downstream Manhole, Survey Ends - 4:50AM

Observation photos (1)

  • General Observation - WHITE BUUILD UP ON PIPE

    8 ft. - General Observation - WHITE BUUILD UP ON PIPE

Observations (34)

DistanceCodeObservation
70.5FCH
54.1FCH
122.7FCSL
86.7FCH
94.4FCH
74.8FCSL
0MWM
86.7FCH
94.4FCH
0MWL
102.7FCH
43.1FCSL
43.1FCSL
114.5FLH
8MGOWHITE BUUILD UP ON PIPE
106.5FCH
110.6FCSL
30.9FCSLIGHT
54.1FCSL
70.5FCH
131.3FCSL
131.4TFCCapped
30.9FCHAIRLINE
47.8TFOpen
134.2MGOConn. @ Mh, 3 O' Clock. Active
0AMH4:25AM
90.4FCH
131.3FCSL
39.4FCH
134.5AMH4:50AM
74.8FCSL
102.7FLH
106.5FCSL
122.7FCH

Properties (4)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime