Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2018, 07:46 AM
  • 15 1125_15 1124 _30032018_010238.mp4

Date
03/30/2018
W/O
691318
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00615
PipeID
P12885
Time
12:46 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5515
Sewer Name
15 MERCED TRUNK, SECTION 2
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_691318_TV15100_MAR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
15 1124
Downstream MH
15 1125
Dir. of Survey
Upstream
Length Surveyed
350.4 ft.
Total Length
350.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 15 1124 to 15 1125
MH: 15 1124MH: 15 1125upstream0 ft. AMH - Upstream Manhole, Survey Ends - 15 112536.1 ft. DSF - Deposits Settled Fine, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish53.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"58.3 ft. DSF - Deposits Settled Fine, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start61.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"122.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"125 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"181.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"230.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"241.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"314.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"344 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"350.4 ft. AMH - Downstream Manhole, Survey Begins - 15 1124350.4 ft. MWL - Water Level, 15 %of cross sectional area350.4 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • Deposits Settled Fine,  15 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    292.1 ft. - Deposits Settled Fine, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
6.4TF
288.8TF
314.3DSF
36TF
292.1DSF
168.6TF
0AMH15 1124
0MWL
207.6TF
228.1TF
297.1TFC
0MWM
108.6TF
120.3TF
225.4TF
350.4AMH15 1125

Properties (4)

additional_info
SC358721
custom_field_two
3
customer
LACSD
datetime
2018-03-30T00:46:52-07:00