Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2018, 09:13 AM
  • 15 1117_15 1116 _30032018_024005.mp4

Date
03/30/2018
W/O
691318
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00615
PipeID
P12877
Time
2:13 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5515
Sewer Name
15 MERCED TRUNK, SECTION 2
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_691318_TV15100_MAR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 1117
Downstream MH
15 1116
Dir. of Survey
Downstream
Length Surveyed
338.2 ft.
Total Length
338.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 1117 to 15 1116
MH: 15 1117MH: 15 1116downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 11170 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH0 ft. MWM - Water Mark, 25 %of cross sectional area52.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"69.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"102.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"105.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"150.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"183.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"201.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"248.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"276.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"299.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"332.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"338 ft. MGO - General Observation - GHOUT THE REACH, FROM 03 TO 09 O'CLOCK, 5%338.2 ft. AMH - Downstream Manhole, Survey Ends - 15 1116

Observations (17)

DistanceCodeObservation
338.2AMH15 1116
0MWL
52.1TFC
183.6TF
0AMH15 1117
332.7TF
299.6TFC
69.6TF
0MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
0MWM
102.2TF
248.9TFC
338MGOGHOUT THE REACH, FROM 03 TO 09 O'CLOCK, 5%
105.3TF
150.5TFC
201.5TF
276.3TF

Properties (4)

additional_info
SC358721
custom_field_two
3
customer
LACSD
datetime
2018-03-30T02:13:39-07:00