Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2018, 11:12 AM
  • 15 1116_15 1115 _30032018_042624.mp4

Date
03/30/2018
W/O
691318
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00615
PipeID
P12876
Time
4:12 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5515
Sewer Name
15 MERCED TRUNK, SECTION 2
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_691318_TV15100_MAR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 1116
Downstream MH
15 1115
Dir. of Survey
Downstream
Length Surveyed
290.1 ft.
Total Length
290.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 1116 to 15 1115
MH: 15 1116MH: 15 1115downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 11160 ft. MWM - Water Mark, 25 %of cross sectional area18.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"69.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"72.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"123.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"147.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"168.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"180.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"225.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"257.8 ft. MMC - Material Change, Not know272.6 ft. MMC - Material Change, Vitrified clay pipe273.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"290 ft. MGO - General Observation - GHOUT THE REACH, FROM 03 TO 09 O'CLOCK, 5%290.1 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH290.1 ft. AMH - Downstream Manhole, Survey Ends - 15 1115

Observations (19)

DistanceCodeObservation
168.5TFC
120.3TFC
290MGOGHOUT THE REACH, FROM 03 TO 09 O'CLOCK, 5%
18.6TFC
290.1MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
72.2TFC
147.4TF
0MWL
225.6TFC
0AMH15 1116
257.8MMC
84.9TF
273.9TF
123.1TFC
290.1AMH15 1115
180.8TFC
272.6MMC
69.4TF
0MWM

Properties (4)

additional_info
SC358721
custom_field_two
3
customer
LACSD
datetime
2018-03-30T04:12:44-07:00