- Date
- 04/25/2016
- W/O
- 563419
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00141
- PipeID
- P09834
- Time
- 10:14 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3325
- Sewer Name
- C JOINT OUTFALL C - UNIT 8C
- City
- HAWAIIAN GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_563419_TV19012_APRIL2016
- Sewer Type
- GRAVITY
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- C 0371
- Downstream MH
- C 0370
- Dir. of Survey
- Downstream
- Length Surveyed
- 618.4 ft.
- Total Length
- 618.4 ft.
- Structural Index
- 3
- Structural Quick
- 3X2X
- Structural Rating
- 615
- O&M Index
- 3
- O&M Quick
- 423W
- O&M Rating
- 368
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 983
Pipe schematic from manhole C 0371 to C 0370 Observation photos (4)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

576.2 ft. - Infiltration Runner, from 10 to 11 o'clock, within 8 inches of joint: YES