Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 21, 2018, 12:24 PM
  • 02 0375_02 0374_4212018_065210.mp4

Date
04/21/2018
W/O
0701224
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00250
PipeID
P02691
Time
5:24 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0834
Sewer Name
02 DOWNEY AVENUE EXTENSION TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Capital Improvement Program Assesment
Project
20180220MDM_DOWNEY_AVENUE_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0376
Downstream MH
02 0375
Dir. of Survey
Downstream
Length Surveyed
332 ft.
Total Length
332 ft.
Structural Index
2
Structural Quick
392C
Structural Rating
65
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
65
Pipe schematic from manhole 02 0376 to 02 0375
MH: 02 0376MH: 02 0375downstream0 ft. AMH - Upstream Manhole, Survey Begins - 6:50AM0 ft. MWL - Water Level, 10 %of cross sectional area - DVD READS MH 375 TO 374 IS 376 TO 3750 ft. MWM - Water Mark, 30 %of cross sectional area8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H16.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H28.2 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL28.2 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL32.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H33 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active35.3 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - SL35.3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H51.5 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H56.2 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL56.6 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H67.7 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H75.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL75.9 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL77.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped79 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H87.2 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL95.6 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H95.6 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - H99.9 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H103.3 ft. FC - Fracture Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES - H108.9 ft. FL - Fracture Longitudinal, at 08 TO 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS108.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H108.9 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS108.9 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS108.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped108.9 ft. FL - Fracture Longitudinal, at 08 TO 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS160.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped175.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT178.4 ft. FS - Fracture Spiral, from 11 to 02 o'clock, within 8 inches of joint: YES, Start - SLIGHT210.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL210.5 ft. FS - Fracture Spiral, from 11 to 02 o'clock, within 8 inches of joint: YES, Finish - SLIGHT220.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped271.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped331.5 ft. FL - Fracture Longitudinal, at 08 TO 04o'clock, within 8 inches of joint: YES, Finish - 15% SLIGHT AT JOINTS331.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN331.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 60% SLIGHT AT JOINTS331.5 ft. FL - Fracture Longitudinal, at 08 TO 04 o'clock, within 8 inches of joint: YES, Finish - 15% HAIRLINE AT JOINTS331.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 60% HAIRLINE AT JOINTS332 ft. AMH - Downstream Manhole, Survey Ends - 7:30AM

Observation photos (1)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    175.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

Observations (45)

DistanceCodeObservation
95.6FCH
0AMH6:50AM
8FCHAIRLINE
16.3FLH
28.2FCSL
331.5FL15% SLIGHT AT JOINTS
175.1FLSLIGHT
35.3FLSL
331.5MGOConn. @ Mh, 3 O' Clock. OPEN
75.9FLSL
210.5FLSL
220.1TFCCapped
28.2FCSL
33TFActive
75.9FCSL
103.3FCH
79FLH
56.6FCH
108.9FLHAIRLINE AT JOINTS
95.6FCH
178.4FSSLIGHT
51.5FCH
0MWLDVD READS MH 375 TO 374 IS 376 TO 375
108.9FCH
87.2FCSL
331.5FC60% SLIGHT AT JOINTS
108.9FCSLIGHT AT JOINTS
332AMH7:30AM
108.9FCHAIRLINE AT JOINTS
56.2FCSL
108.9TFCCapped
32.4FCH
99.9FCH
331.5FL15% HAIRLINE AT JOINTS
35.3FCH
210.5FSSLIGHT
8FLSLIGHT
271.8TFCCapped
331.5FC60% HAIRLINE AT JOINTS
77.1TFCCapped
160.7TFCCapped
67.7FCH
0MWM
8FCH
108.9FLSLIGHT AT JOINTS

Properties (4)

custom_field_three
SPRIAL SLIGHT JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2018-04-21T05:24:26-07:00