- Date
- 05/12/2016
- W/O
- 568953
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00827
- PipeID
- P16964
- Time
- 12:53 PM
- Certificate
- U-507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3250
- Sewer Name
- 22 SUNFLOWER TRUNK
- City
- GLENDORA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_568953_TV22063_MAY2016
- Sewer Type
- GRAVITY
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 22 0616
- Downstream MH
- 22 0615A
- Dir. of Survey
- Downstream
- Length Surveyed
- 285.3 ft.
- Total Length
- 285.3 ft.
- Structural Index
- 3
- Structural Quick
- 3H00
- Structural Rating
- 138
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 138
Pipe schematic from manhole 22 0616 to 22 0615A Observation photos (4)

0 ft. - Water Mark, 20 %of cross sectional area

51.7 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

52.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - WANDERING

192.7 ft. - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 4"