Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 6, 2016, 05:09 AM
  • 22 0691_22 0690_20160505_232546.mp4

Date
05/05/2016
W/O
568953
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00827
PipeID
P17045
Time
10:09 PM
Certificate
U- 109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K 3203
Sewer Name
22 SUNFLOWER TRUNK
City
LA VERNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
15
Purpose
Routine Assessment
Project
WO_568953_TV22063_MAY2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
22 0691
Downstream MH
22 0690
Dir. of Survey
Downstream
Length Surveyed
264.7 ft.
Total Length
264.7 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
156
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
158
Pipe schematic from manhole 22 0691 to 22 0690
MH: 22 0691MH: 22 0690downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 06910 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"19 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"94.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"99.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"169.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"174.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"244 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"248.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"262 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish264.7 ft. AMH - Downstream Manhole, Survey Ends - 22 0690264.7 ft. VC - Vermin Cockroach

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
169.2TF
99.6TFC
264.7AMH22 0690
0AMH22 0691
0MWM
248.9TFC
13.9TFC
94.5TFC
244TFC
262SAV
0VC
264.7VC
19TF
2SAV
174.1TFC
0MWL

Properties (4)

additional_info
SC300651
custom_field_two
3
customer
LACSD
datetime
2016-05-05T22:09:18-07:00