Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2016, 07:48 AM
  • 22 0663_22 0662_20160509_020758.mp4

Date
05/09/2016
W/O
568953
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00827
PipeID
P17011
Time
12:48 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3247
Sewer Name
22 SUNFLOWER TRUNK
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
22
Purpose
Routine Assessment
Project
WO_568953_TV22063_MAY2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0663
Downstream MH
22 0662
Dir. of Survey
Downstream
Length Surveyed
370.1 ft.
Total Length
370.1 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
219
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
221
Pipe schematic from manhole 22 0663 to 22 0662
MH: 22 0663MH: 22 0662downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 06630 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. VC - Vermin Cockroach2 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - Magnesium hydroxide coating start5 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"27.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"33.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"102.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"107.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"176.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"182 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"251.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"256.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"321.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"326 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"367.4 ft. MGO - General Observation - Magnesium hydroxide coating finish368 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish370.1 ft. AMH - Downstream Manhole, Survey Ends - 22 0662370.1 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK370.1 ft. VC - Vermin Cockroach

Observations (22)

DistanceCodeObservation
27.7TFA
321.2TFC
370.1AMH22 0662
5TBA
256.3TFA
176.6TFC
370.1MGOCONNECTION AT THE MH 3 O'CLOCK
326TFC
182TFC
367.4MGOMagnesium hydroxide coating finish
2SAV
251.6TFC
102.2TFA
33.1TFA
370.1VC
107.4TFC
0AMH22 0663
0MWL
0MWM
368SAV
2MGOMagnesium hydroxide coating start
0VC

Properties (4)

additional_info
SC305346
custom_field_two
3
customer
LACSD
datetime
2016-05-09T00:48:29-07:00