Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2016, 10:46 AM
  • C 0359_C 0358_27042016_034742.mp4

Date
04/27/2016
W/O
563382
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00140
PipeID
P09822
Time
3:46 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3329
Sewer Name
C JOINT OUTFALL C - UNIT 8B
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
09
Purpose
Routine Assessment
Project
WO_563382_TV19020_APRIL2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Upstream MH
C 0359
Downstream MH
C 0358
Dir. of Survey
Downstream
Length Surveyed
871.5 ft.
Total Length
871.5 ft.
Structural Index
3
Structural Quick
3b2b
Structural Rating
870
O&M Index
2
O&M Quick
412b
O&M Rating
352
Overall Index
2
Overall Quick
Overall Rating
1222
Pipe schematic from manhole C 0359 to C 0358
MH: C 0359MH: C 0358downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 03590 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start827.4 ft. MGO - General Observation - RUN LIST STATES MH AT 829'.870.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish870.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish870.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish870.4 ft. IR - Infiltration Runner, at 12 o'clock, within 8 inches of joint: NO871.5 ft. AMH - Downstream Manhole, Survey Ends - C 0358

Observation photos (4)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Runner, at 12 o'clock, within 8 inches of joint: NO

    870.4 ft. - Infiltration Runner, at 12 o'clock, within 8 inches of joint: NO

Observations (12)

DistanceCodeObservation
0AMHC 0359
870.4IR
870.3DAGS
2SSS
0MWM
870.3SAP
827.4MGORUN LIST STATES MH AT 829'.
871.5AMHC 0358
2DAGS
2SAP
0MWL
870.3SSS

Properties (4)

additional_info
SC305605
custom_field_two
2
customer
LACSD
datetime
2016-04-27T03:46:41-07:00