- Date
- 04/27/2016
- W/O
- 563382
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00140
- PipeID
- P09825
- Time
- 12:14 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3329
- Sewer Name
- C JOINT OUTFALL C - UNIT 8B
- City
- HAWAIIAN GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_563382_TV19020_APRIL2016
- Sewer Type
- GRAVITY
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Upstream MH
- C 0362
- Downstream MH
- C 0361
- Dir. of Survey
- Downstream
- Length Surveyed
- 715.8 ft.
- Total Length
- 715.8 ft.
- Structural Index
- 3
- Structural Quick
- 3[2[
- Structural Rating
- 704
- O&M Index
- 2
- O&M Quick
- 3P2[
- O&M Rating
- 536
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 1240
Pipe schematic from manhole C 0362 to C 0361 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

12 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

294.1 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start